Skip to content

VAE anomaly detection on medical images in Python

What ships today, and what is coming

Today: vae_anomaly.py: train on normal images, score any image by reconstruction residual, AUROC when labels exist. No weights are shipped and there is no inference API: the scripts are reference implementations that read any pardesline dataset.

Coming: one-line model access. The same registry pattern as datasets, a model manifest (source, weights URI, licence, input type, task, memory needs, provenance) and pl.load_model(...) / pl.run(model, dataset). This page keeps its URL. Follow and vote on the model registry tracking issue; model manifests can be contributed now from templates/new_model/.

Reference scripts: vae_anomaly.py (shipped in the wheel under pardesline/skills/vae-anomaly-detection/scripts/, served by the MCP tool get_skill).

Runnable example: examples/vae_anomaly_hippocampus/run.py, executed on 2026-10-16; its outputs are committed next to it.

Reconstruction-based anomaly detection with a VAE

The idea

Train a model that only knows normal data. At test time it reconstructs the normal part of an input and smooths away what it has never seen; the residual |x - x_hat| highlights the anomaly without a single abnormal training example. "A model that only knows healthy teeth reveals the cavity."

The VAE

Encoder q(z|x) = N(mu(x), diag(sigma^2(x))), decoder p(x|z), loss

L = E_q[ -log p(x|z) ]  +  beta * KL( q(z|x) || N(0, I) )
  = reconstruction (L2 / BCE / SSIM)  +  beta * 1/2 sum (mu^2 + sigma^2 - log sigma^2 - 1)

with the reparameterisation z = mu + sigma * eps. The KL term makes the latent space smooth and prevents the identity mapping; beta sets the trade-off: beta < 1 sharper reconstructions, weaker regularisation; beta > 1 (beta-VAE) more disentangled, blurrier. For anomaly detection a slightly under-capacity model is the point: it must not be able to reconstruct the anomaly.

Reference design (dental panoramic X-ray, 1 x 256 x 256): encoder of 5 blocks Conv2d(3x3, stride 2) + BatchNorm + ReLU (32-64-128-256-512 channels) to 8 x 8, fully connected to mu, logvar of 512 dims; decoder mirrors with ConvTranspose2d; sigmoid output; loss L2 (or BCE) + KL; Adam 1e-3 to 1e-4, batch 32, 100-300 epochs; cyclic or warm-up annealing of beta (0 -> 1 over 10 epochs) avoids posterior collapse. For volumes: 3D convolutions on 64^3 or 96^3 patches, latent 256-1024.

Residual maps and scores

  1. r = |x - x_hat| (or 1 - SSIM map, which is less sensitive to small intensity shifts).
  2. Smooth with a Gaussian (sigma 2-4 px) to suppress pixel noise.
  3. Image score = mean of the top 1 % of r (or the 99th percentile); pixel map = r thresholded.
  4. Threshold from the validation set of normal images: e.g. the 99th percentile of normal scores for a 1 % false-positive rate; never from the test set.
  5. Morphological opening removes 1-2 px specks; keep components above a minimum area in physical units (mm^2 via the pixel spacing).

Variants that help: masking the field of view (teeth region only), averaging residuals over several latent samples (the VAE is stochastic), comparing against the k nearest normal training images instead of a single reconstruction.

Evaluation (see evaluation-metrics-3d)

  • Image level: AUROC and AUPRC of the score on a test set with both classes.
  • Pixel level: AUROC / AUPRC on pixels when masks exist (AUPRC is the honest one at 1 % anomaly pixels), Dice of the thresholded map at the chosen operating point, per-lesion detection rate at an IoU of 0.3.
  • Baselines to beat: a Gaussian on raw pixels, PCA reconstruction, k-NN on DINOv3 features (dinov3-dense-features); report them.

Honest limits

  • The decoder may reconstruct the anomaly when it is large or low-frequency (a bright implant is "easy"): the score then drops. Limit capacity, add noise or masking to the input (denoising / inpainting VAE).
  • Blurry reconstructions produce residuals on every edge: SSIM or perceptual losses, or compare at a lower resolution.
  • Domain shift (another scanner, exposure) raises every score: normalise intensities, calibrate thresholds per site, monitor the score distribution.
  • Subtle anomalies below the reconstruction error floor are invisible; report the floor (mean residual on normal images).
  • A detector that never saw caries can still flag them, but it cannot name them: pair with a classifier when a diagnosis is needed.

Alternatives worth knowing

Feature-space methods (PatchCore, k-NN on frozen DINOv3 patch tokens) beat reconstruction on many 2D benchmarks and need no training; latent-space distance with a JEPA encoder (jepa-pretraining) scales to 3D; diffusion restoration (AnoDDPM) gives sharper residuals at 100x the compute; for 3D volumes, a 3D VAE on patches or slice-wise 2D with aggregation.

Building normal-only sets with pardesline

Healthy controls: ixi_brain_mri (healthy subjects, T1/T2/PD), hf_openmind (mostly healthy OpenNeuro cohorts), openneuro_ds000228; CT controls can be cut from totalsegmentator_ct regions without lesions; abnormal test cases: msd_task01_braintumour, hf_kits23 (tumours), luna16 (nodules). Split by patient, keep the licence.

scripts/vae_anomaly.py: 2D VAE (256 px) with beta warm-up, training on a folder of normal images, scoring of a folder with residual heatmaps (PNG) and image scores (CSV), evaluation (AUROC / AUPRC) when a labels file is given. Needs torch, pillow; runs a smoke test on synthetic images with --smoke.