Skip to content

Point cloud registration with RANSAC, FPFH and ICP

Reference scripts: registration_eval.py.

Point-cloud registration: RANSAC + FPFH + ICP, done properly

The pipeline and why two stages

A single ICP converges only from a nearby pose (typically < 30 deg, < one object radius). The global stage finds that pose from features; the local stage polishes it.

downsample (voxel v)  ->  normals (r_n = 2v)  ->  FPFH (r_f = 5v)
      ->  RANSAC on feature correspondences (d_max = 1.5v)   [global, coarse]
      ->  ICP point-to-plane on the full-resolution clouds (d_max = 0.4v)   [local, fine]
      ->  metrics: fitness, inlier RMSE, transform T (4x4)

Everything scales with one number, the voxel size v, which should be 2-5 times the point spacing and about 1 % of the object's bounding-box diagonal (pardesline's voxel_size=0 picks 1.3 % of the diagonal, the Open3D tutorial setting). If the units are wrong (mm vs m) every radius is wrong: check cloud.frame.describe() first.

FPFH in two sentences

For each point, the Simplified Point Feature Histogram encodes the angles (alpha, phi, theta of the Darboux frame) between its normal and the normals of neighbours within r_f; FPFH re-weights each point's SPFH with its neighbours' SPFHs (1/d weights), giving a 33-bin histogram that is rotation-invariant and cheap (O(N k)). It needs normals that are consistently oriented; estimate them on the downsampled cloud with r_n = 2v, max_nn=30.

RANSAC on correspondences

Sample n = 3 correspondences by feature matching (mutual filter on: both directions must agree), estimate a rigid transform (Umeyama / SVD), prune with the edge-length checker (edge_length_threshold = 0.9: the three pairwise distances must agree within 10 %) and the distance checker (d_max = 1.5v), count inliers. Stop after max_iteration (100 000) or when the confidence (0.999) is reached. Output: T_ransac, fitness (inlier fraction of the source), inlier RMSE.

ICP refinement

Point-to-plane minimises sum ((R p_i + t - q_i) · n_qi)^2 - it converges in far fewer iterations than point-to-point and slides along surfaces instead of fighting them; it needs target normals. Point-to-point is the fallback when normals are unreliable (sparse, noisy LiDAR). Correspondence distance 0.4v on the full-resolution clouds; stop on relative_fitness and relative_rmse below 1e-6 or at max_iteration. Generalised ICP (plane-to-plane, covariance-weighted) and robust kernels (Tukey, Cauchy on the residual) help with outliers; multi-scale ICP (v, v/2, v/4) helps with large residual error after RANSAC.

Parameters, by name, in pardesline

import pardesline as pl

fixed = pl.load("scan.ply").with_frame("sensor", "mm")
moving = pl.load("atlas.ply").with_frame("sensor", "mm")

aligned = fixed.align(moving)  # registration.ransac_icp_pipeline, voxel_size auto
aligned = fixed.run(
    "registration.ransac_icp_pipeline",
    moving=moving,
    voxel_size=2.0,  # mm; 2-5x the point spacing
    normal_radius_factor=2.0,
    fpfh_radius_factor=5.0,
    distance_threshold_factor=1.5,
    mutual_filter=True,
    ransac_n=3,
    edge_length_threshold=0.9,
    ransac_max_iteration=100000,
    ransac_confidence=0.999,
    icp_threshold_factor=0.4,
    icp_estimation_method="point_to_plane",
    icp_max_iteration=30,
    icp_relative_fitness=1e-6,
    icp_relative_rmse=1e-6,
)
aligned.transform  # {'fitness', 'inlier_rmse', 'transformation_matrix', ...} from <output>.json

Two-stage control: registration.ransac_global alone (coarse pose, to inspect before refining) and registration.icp_refinement (which runs its own RANSAC pre-pass unless the clouds already overlap: ransac_seed_fitness is the fitness below which it falls back to a centre-of-mass initialisation). Set ransac_with_scaling=True only when the two clouds come from different devices with unknown scale (photogrammetry vs scanner); never for LiDAR.

Parameter effects, from experience:

Symptom Likely cause Change
RANSAC fitness < 0.3, ICP does nothing features meaningless: v too small (noise) or too large (no detail) scan v over 0.5x-4x; check units
Converges to a mirrored / rotated pose symmetric object (sphere, cylinder, vertebra body) add landmarks or a prior pose; use ransac_n=4; verify with TRE, not fitness
Fitness high, RMSE high correspondence distance too generous lower icp_threshold_factor to 0.2-0.3
Fitness drops when overlap is partial fitness counts source points; partial overlap caps it judge by inlier RMSE and pose error on the overlapping region; crop first
Drift on flat scenes (floors, walls) point-to-plane slides along planes point-to-point, or add walls/edges, or constrain DoF
Different scale mm vs m, or photogrammetry ransac_with_scaling=True, then fix the scale and re-run rigid

Metrics: which ones mean something

  • Fitness = inliers / source points at distance d_max. Depends on d_max; compare runs only at the same threshold. Caps at the overlap ratio.
  • Inlier RMSE = RMS distance of inliers. Lower bound is the noise level of the scanner (0.5 mm for the ultrasound use case): below that you are measuring noise, not alignment.
  • Pose error against a known transform (synthetic tests, phantoms): rotation error arccos((tr(R_est R_true^T) - 1) / 2) in degrees, translation error at the object centre ||T_est c - T_true c|| (not the raw translation vector, which mixes with rotation about the origin).
  • Target registration error (TRE): distance between corresponding landmarks not used by the algorithm. The only metric a clinician accepts.
  • Chamfer / Hausdorff between the aligned surfaces: see the evaluation-metrics-3d skill. Hausdorff is dominated by one outlier; report the 95th percentile.

scripts/registration_eval.py runs the full pipeline on a bundled cloud with a known synthetic transform and prints all of these.

Non-rigid: Coherent Point Drift

CPD treats the moving cloud as Gaussian mixture centroids and the fixed cloud as samples; EM alternates responsibilities and a displacement field that is regularised to be smooth (beta = kernel width, lambda_val = regularisation weight, w = outlier fraction). deformable_registration.cpd_deformable exposes them; low_rank=True with num_eig makes it tractable above ~10 k points. Use it after a rigid alignment, for organ motion, breathing, or atlas-to-patient shape adaptation; never as a first stage. Validate with Jacobian-determinant positivity of the displacement (no folding) and TRE.

Medical specifics

  • Atlas to patient (see atlas-label-transfer): the scan is the fixed reference, the atlas moves. Labels travel with point order, so keep the atlas point order (pardesline's output keeps it).
  • Ultrasound reconstructions are noisy and partial: v 2-3 mm, point-to-plane, expect fitness 0.6-0.9, RMSE near the noise floor.
  • CBCT / intra-oral scans: 0.1-0.2 mm spacing, v 0.5 mm; symmetric teeth need the arch as context, never a single tooth.
  • Multimodal volumes (CT vs MR) are not a point-cloud problem: use intensity-based registration (multimodal-rigid-registration skill).

Datasets to practise on

open3d_icp_demo (indoor fragments, sensor frame, m), open3d_bunny (synthetic transforms), kitti_raw_2011_09_26_drive_0001 (consecutive sweeps, sensor frame, m; odometry-style), medshapenet (two instances of the same organ for shape registration), c3vd_endoscopy_splats (points role).

ds = pl.load("open3d_icp_demo")
pair = ds["pair_0_1"]
moved = pair.target.align(pair.source, voxel_size=0.05)  # metres
print(moved.transform["fitness"], moved.transform["inlier_rmse"])